Fire Point Extinguisher Services
Commercial addressable fire alarm control panel, manual call point, and smoke detector in an Irish building

Certified Fire Alarm Systems (I.S. 3218) Across Ireland

Design, supply, installation, commissioning, and quarterly maintenance of addressable and conventional commercial fire alarm systems across Ireland.

Engineered in strict compliance with Irish Standard I.S. 3218 to protect lives, safeguard property, and satisfy local Fire Officer and HSA requirements.

Phil: 083 1941701
Dublin Office: 01 9081706info@firepointservices.ieNSAI I.S. 291 Certified

Irish Standard

I.S. 3218:2013+A1:2019

System Types

Addressable & Conventional

Protection Categories

L1, L2, L3, L4, L5 & P1/P2

Mandatory Servicing

Quarterly I.S. 3218 Visits

NSAI I.S. 3218 Certified · L1–L5 & P1–P2 · Dublin & Leinster Engineering

Early-Warning Fire Detection Engineered to Irish Standard I.S. 3218

Under the Fire Services Act 1981–2003 and the Safety, Health and Welfare at Work Act 2005, every commercial building in Ireland requires an appropriate fire detection and alarm system. We design, commission, and certify conventional and addressable systems tailored to your building Fire Safety Certificate.

01 · Pinpoint Device-Level Location Identification

Addressable Intelligent Fire Alarm Systems

Each optical smoke sensor, heat detector, and call point has a unique digital address — displaying the exact room and floor on the control panel LCD during an activation.

02 · 2, 4, 8 & 16-Zone EN 54 Certified Panels

Conventional Multi-Zone Commercial Fire Panels

Cost-effective, rock-solid fire detection for retail units, restaurants, small offices, and workshops with clear zone LED indicators and sounder circuits.

03 · EN 54 Approved · False-Alarm Rejection

Multi-Sensor Optical, Thermal & CO Fire Detectors

Intelligent dual-criteria sensors combine photoelectric smoke and rate-of-rise thermal detection to provide rapid response while eliminating steam or dust false alarms.

04 · Mandatory 4 Visits Per Year (25% Per Quarter)

I.S. 3218 Quarterly Servicing, Logbooks & Certification

Irish Standard I.S. 3218 requires commercial fire alarms to be inspected quarterly by a competent engineer so 100% of devices are tested over each 12-month cycle.

Configure Your Fire Alarm Systems Specification

Select your property profile, number of detection devices / call points, and preferred support mode to preview our recommended Irish compliant specification.

8 Detection Devices / Call Points
2 Units (Small)16 Units (Mid-size)32+ Units (Enterprise)
Recommended System ArchitectureI.S. 3218 L2 / L3 Category · EN 54

Conventional Commercial Fire Alarm System (2–8 Zones) (8 Detection Devices / Call Points)

Configured for Retail & Office with Smartphone App Control

  • EN 54 4-Zone or 8-Zone Conventional Fire Alarm Control Panel
  • Optical smoke detectors, kitchen rate-of-rise heat detectors & bases
  • Surface/flush red Manual Call Points (MCPs) at all final exits
  • High-output electronic sounder/VAD beacons + Fire Safety Logbook

Free on-site survey & exact quotation across Dublin & Ireland.

Tier 01 · 8–24 DevicesRetail Units, Cafés, Small Offices & Workshops

Conventional Commercial Fire Alarm System (2–8 Zones)

I.S. 3218 L2 / L3 Category · EN 54

  • EN 54 4-Zone or 8-Zone Conventional Fire Alarm Control Panel
  • Optical smoke detectors, kitchen rate-of-rise heat detectors & bases
  • Surface/flush red Manual Call Points (MCPs) at all final exits
  • High-output electronic sounder/VAD beacons + Fire Safety Logbook
Tier 02 · 25–250+ DevicesHotels, Schools, Nursing Homes, Warehouses & Offices

Addressable Multi-Loop Enterprise Fire Detection System

I.S. 3218 L1 Full Coverage · Cause & Effect Programming

  • 1–4 Loop Addressable Fire Control Panel with repeater display option
  • Addressable multi-sensors, beam detectors, duct probes & sounder bases
  • Automatic magnetic door-retainer release, lift recall & HVAC shutdown relays
  • Dual-Path 24/7 ARC Fire Monitoring + I.S. 3218 Commissioning Certificate
Commercial addressable fire alarm control panel, manual call point, and smoke detector in an Irish building

NSAI I.S. 3218:2013+A1:2019

Statutory I.S. 3218 Fire Alarm Requirements in Ireland

NSAI I.S. 3218:2013+A1:2019

Statutory I.S. 3218 Fire Alarm Requirements in Ireland

  • Issued with formal I.S. 3218 Design, Installation, Commissioning, and Handover Certificates
  • Quarterly engineer servicing (every 3 months) is mandatory under I.S. 3218 to maintain compliance
  • Includes on-site Fire Alarm Logbook and zone plan diagram mounted beside the main panel
  • Combine your I.S. 3218 Fire Alarm and I.S. 291 Fire Extinguisher servicing with Fire Point to save time and cost

Certified I.S. 3218 Commercial Fire Alarm Installation & Quarterly Servicing in Dublin

Every commercial building in Dublin requires a compliant fire detection and alarm system under the Fire Services Act and Irish Standard I.S. 3218:2013+A1:2019. We design, install, commission, and quarterly-service addressable and conventional fire alarms.

Dublin City, North, South & West

Serving Dublin hotels, apartment blocks, offices, restaurants, schools, retail units, and warehouses with L1–L5 & P1/P2 category systems, zone plans, and official I.S. 3218 logbooks.

Kildare, Meath, Wicklow & Louth

Combine your quarterly I.S. 3218 fire alarm visits and annual I.S. 291 fire extinguisher servicing under one reliable partner across Dublin, Kildare, Meath, and Wicklow.

Fast Local Site Surveys & Engineer Support

Book your quarterly I.S. 3218 fire alarm inspection or new system survey in Dublin on 01 9081706.

Local Dublin & Leinster Specialisms:

  • Fire Alarm Installation Dublin IS 3218
  • Commercial Fire Alarm Servicing Dublin
  • Quarterly Fire Alarm Testing Dublin
  • Addressable & Conventional Fire Alarms Dublin
Dublin: 01 9081706